Compaq StorageWorks HSZ80 Configuration And Cli Reference Manual page 88

Array controller acs version 8.3
Hide thumbs Also See for StorageWorks HSZ80:
Table of Contents

Advertisement

2–34
Configuring an HSZ80 Array Controller
You can view IDs on this controller with the following command:
SHOW THIS_CONTROLLER FULL
You can view IDs on the other controller with the following command:
SHOW OTHER_CONTROLLER FULL
The valid target ID numbers are 0–15, with one ID reserved for each host controller
on the host bus. When both ports are in use, the 16 target ID numbers are shared
across ports. Once a target ID has been set on one port, that same target may not be
used on the other port.
Using more than one target ID number allows the controller to present more units to
the host. Enclose multiple ID numbers in parentheses and separate each by a comma:
(n1, n2, n3, . . .)
Device SCSI Bus
Device addressing allows the controller to identify the location of devices based on a
port-target-LUN (PTL) number described in "Device PTL Addressing Convention
within the Controller," page 3–36.