Compaq StorageWorks HSZ80 Configuration And Cli Reference Manual page 292

Array controller acs version 8.3
Hide thumbs Also See for StorageWorks HSZ80:
Table of Contents

Advertisement

5–106
CLI Commands
.
ºC
0
32
1
34
2
46
3
37
4
39
5
41
6
43
7
45
8
46
9
48
If any of the setpoints assigned to a slave EMU do not match the corresponding
setpoints assigned to the master EMU, the slave EMU settings change to match the
corresponding master EMU settings.
Refer to the enclosure documentation for detailed information about setting the EMU
temperature set points.
FANSPEED=HIGH
FANSPEED=AUTOMATIC (Default)
Sets the speed at which the fan operates.
Select FANSPEED=HIGH to force the fans in all connected cabinets to operate at
high speed continuously.
Select FANSPEED=AUTOMATIC to allow the EMU to control the fan speed for the
fans in all connected cabinets.
Table 5–7 EMU Set Point Temperatures
ºF
ºC
ºF
10
50
20
11
52
21
12
54
22
13
55
23
14
57
24
15
59
25
16
61
26
17
63
27
18
64
28
19
66
29
ºC
ºF
ºC
68
30
86
70
31
88
72
32
90
73
33
91
75
34
93
77
35
95
79
36
97
81
37
99
82
38
100
84
39
102
ºF
ºC
ºF
40
104
41
106
42
108
43
109
44
111
45
113
46
115
47
117
48
118
49
120

Advertisement

Table of Contents
loading

Table of Contents

Save PDF