5–66
CLI Commands
TRANSFER_RATE_REQUESTED = 20MHZ (synchronous 10.00 MHZ negotiated)
LOCAL
Size: 4108970 blocks
Configuration being backed up on this container
DISK30300
DEC
Switches:
NOTRANSPORTABLE
TRANSFER_RATE_REQUESTED = 20MHZ (synchronous 10.00 MHZ negotiated)
LOCAL
Size: 4108970 blocks
Configuration being backed up on this container
This example shows how to initialize stripeset STRIPE1 with the default chunk size.
The chunk size is not specified, so the controller initializes the unit with the default
chunk size.
ADD DISK DISK10100 1 1 0
ADD DISK DISK20100 2 1 0
ADD DISK DISK30100 3 1 0
ADD STRIPESET STRIPE1 DISK10100 DISK20100 DISK30100
INITIALIZE STRIPE1
This example shows how to initialize RAIDset RAID9 with a chunk size of 20:
ADD DISK DISK10200 1 2 0
ADD DISK DISK20200 2 2 0
ADD DISK DISK30200 3 2 0
ADD RAIDSET RAID9 DISK10200 DISK20200 DISK30200
INITIALIZE RAID9 CHUNKSIZE=20
This example shows how to initialize DISK40400 and preserve the data after it is
removed (reduced) from a mirrorset:
REDUCE DISK40400
INITIALIZE DISK40400 NODESTROY