Compaq StorageWorks HSZ80 Configuration And Cli Reference Manual page 173

Array controller acs version 8.3
Hide thumbs Also See for StorageWorks HSZ80:
Table of Contents

Advertisement

NOTE: Figure 4–1 shows an example of a heterogeneous host configuration. For
supported host operating systems, refer to the HSZ80 Array Controller ACS
Version 8.3 Release Notes .
Windows
NT
Controller device bus
D0
D1
D2
D100
Figure 4–1. Setting Host Modes
To reassign targets 2 and 3 to the Windows NT Server mode, use the following
syntax:
SET THIS_CONTROLLER HOST_FUNCTION = (2,D)
SET THIS_CONTROLLER HOST_FUNCTION = (3,D)
The controller will then use default SCSI-2 behavior when units D0–D2 and
D100–D102 are accessed by a host. It will also use Windows-NT-compatible SCSI-2
behavior when units D200–D202 and D300–D302 are accessed by a Windows NT
host.
Host bus
Port 1
Port 2
HSZ80
D101
D102
D200
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
Digital
OpenVMS
Controller device bus
D201
D202
D300
D301
4–25
D302
CXO6477A