NOTE: Figure 4–1 shows an example of a heterogeneous host configuration. For
supported host operating systems, refer to the HSZ80 Array Controller ACS
Version 8.3 Release Notes .
Windows
NT
Controller device bus
D0
D1
D2
D100
Figure 4–1. Setting Host Modes
To reassign targets 2 and 3 to the Windows NT Server mode, use the following
syntax:
SET THIS_CONTROLLER HOST_FUNCTION = (2,D)
SET THIS_CONTROLLER HOST_FUNCTION = (3,D)
The controller will then use default SCSI-2 behavior when units D0–D2 and
D100–D102 are accessed by a host. It will also use Windows-NT-compatible SCSI-2
behavior when units D200–D202 and D300–D302 are accessed by a Windows NT
host.
Host bus
Port 1
Port 2
HSZ80
D101
D102
D200
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
Digital
OpenVMS
Controller device bus
D201
D202
D300
D301
4–25
D302
CXO6477A
Need help?
Do you have a question about the StorageWorks HSZ80 and is the answer not in the manual?