Add Mirrorset - Compaq StorageWorks HSZ80 Configuration And Cli Reference Manual

Array controller acs version 8.3
Hide thumbs Also See for StorageWorks HSZ80:
Table of Contents

Advertisement

ADD MIRRORSET

Names a mirrorset and adds it to the controller configuration.
Syntax
ADD MIRRORSET mirrorset-name disk-name1 [disk-nameN]
Parameters
mirrorset-name
Assigns a name to the mirrorset. This is the name used with the ADD UNIT
command to identify the mirrorset as a host-addressable unit.
The mirrorset name must start with a letter (A through Z) and may consist of a
maximum of nine characters including letters A through Z, numbers 0 through 9,
periods (.), dashes (-), or underscores (_).
IMPORTANT: It is common to name a mirrorset MIRR n , where n is a sequentially
assigned, unique identifier. Other naming conventions are acceptable, but this
naming convention presents both the type of container and its unique identifier in
an intuitive manner.
disk-name1 [disk-nameN]
Identifies the disk drives making up the mirrorset. A mirrorset may contain one to six
disk drives.
Switches
COPY=FAST
COPY=NORMAL (Default)
Sets the speed at which the controller copies data to a new member from normal
mirrorset members when data is being mirrored to the storageset's disk drives.
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
5–11