Compaq StorageWorks HSZ80 Configuration And Cli Reference Manual page 170

Array controller acs version 8.3
Hide thumbs Also See for StorageWorks HSZ80:
Table of Contents

Advertisement

4–22
Configuring Storagesets
SCSI-2 Mode
As you add storage units and set SCSI IDs over the CCL or above its location, the
CCL immediately and automatically moves into the next available free space, which
would be the lowest available Target ID/LUN setting.
IMPORTANT: If you delete a unit at a setting below the CCL setting, the CCL
does not automatically move to that setting. Instead, it only moves to the lowest
deleted unit's setting when you restart the controller.
SCSI-3 Mode
The CCL always remains in a fixed location. It is always located at LUN 0 of every
target ID. If you have the CCL enabled, the controller will let you configure a device
above LUN 0 of each target ID.