Setting SCSI Target ID Numbers

In a subsystem, every SCSI device is assigned its own SCSI ID number. Setting an ID
number, though, really depends on which SCSI bus you are talking about—the host
SCSI bus or the controller device bus, which are both shown in Figure 2–7.
Host
Figure 2–7. Host SCSI Bus and Controller Device Bus
Host SCSI Bus
Each BA370 rack-mountable enclosure in a configuration supports a range of SCSI
target ID numbers. Each controller can access the target ID numbers that you specify
with either of the following commands:
SET THIS_CONTROLLER PORT_1_ID = ( n,n )
or
SET THIS_CONTROLLER PORT_2_ID = ( n,n )
Controller A
Host SCSI bus
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
Controller
device bus
Controller B
CXO6320A
2–33