Compaq StorageWorks HSZ80 Configuration And Cli Reference Manual page 155

Array controller acs version 8.3
Hide thumbs Also See for StorageWorks HSZ80:
Table of Contents

Advertisement

4.
Verify the RAIDset configuration and switches. Use the following syntax:
RAIDset-name
SHOW
5.
Verify the unit configuration and switches. Use the following syntax:
SHOW
unit-number
Example
The following example shows the commands you would use to create RAID1, a three-
member RAIDset:
ADD RAIDSET RAID1 DISK10000 DISK20000 DISK30000
INITIALIZE RAID1
ADD UNIT D300 RAID1
SHOW RAID1
SHOW D300
Configuring a Striped Mirrorset
See "Creating a Storageset and Device Profile," page 3–5 for information about
creating a profile and understanding the switches you can set for this kind of storage
unit.
NOTE: A striped mirrorset cannot be created if the mirrorsets are enabled for
DT_SUPPORT.
To configure a striped mirrorset:
1.
Create—but do not initialize—at least two mirrorsets.
2.
Create a stripeset and specify the mirrorsets it contains. Use the following syntax:
ADD STRIPESET
stripeset-name mirrorset_1 mirrorset_2
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
4–7

Advertisement

Table of Contents
loading

Table of Contents

Save PDF