3.
Present the mirrorset to the host by giving it a unit number the host can recognize.
Optionally, you can append Unit switch values. If you do not specify switch
values, default values are applied. Use the following syntax:
unit-number mirrorset-name switch
ADD UNIT
See "ADD UNIT," page 5–27, for valid switches and values.
4.
Verify the mirrorset configuration and switches. Use the following syntax:
mirrorset-name
SHOW
5.
Verify the unit configuration and switches. Use the following syntax:
SHOW
unit-number
Example
The following example shows the commands you would use to create Mirr1, a two-
member stripeset:
ADD MIRRORSET Mirr1 DISK10000 DISK20000
INITIALIZE MIRR1
ADD UNIT D110 MIRR1
SHOW MIRR1
SHOW D110
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
4–5