ADD UNIT D1 RAID1 PARTITION=1
ADD UNIT D2 RAID1 PARTITION=2
ADD UNIT D3 RAID1 PARTITION=3
ADD UNIT D4 RAID1 PARTITION=4
SHOW RAID1
.
.
.
Partition number
1
2
3
4
.
.
.
Adding a Disk Drive to the Spareset
The spareset is a collection of hot spares that are available to the controller should it
need to replace a failed member of a RAIDset or mirrorset.
Use the following steps to add a disk drive to the spareset. This procedure assumes
that the disks that you are adding to the spareset have already been added to the
controller's list of eligible devices.
1.
Add the disk drive to the controller's spareset list. Use the following syntax:
ADD SPARESET DISK nnnn
Repeat this step for each disk drive you want to add to the spareset.
Size
1915 (0.98
MB)
1915 (0.98
MB)
1915 (0.98
MB)
2371 (1.21
MB)
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
Starting Block
Used by
0
D1
1920
D2
3840
D3
5760
D4
4–13