Initialize Switches - Compaq StorageWorks HSZ80 Configuration And Cli Reference Manual

Array controller acs version 8.3
Hide thumbs Also See for StorageWorks HSZ80:
Table of Contents

Advertisement

Initialize Switches

You can enable the following kinds of switches to affect the format of a disk drive or
storageset:
Chunk size (for stripesets and RAIDsets only)
Save configuration
Destroy/Nodestroy
After you initialize the storageset or disk drive, you cannot change these switches
without reinitializing the storageset or disk drive.
Chunk Size
Specify a chunk size to control the stripesize used for RAIDsets and stripesets:
CHUNKSIZE=DEFAULT lets the controller set the chunk size based on the
number of disk drives (d) in a stripeset or RAIDset. If d < 9, then chunk size =
256. If d > 9, then chunk size = 128.
CHUNKSIZE=n lets you specify a chunk size in blocks. The relationship
between chunk size and request size determines whether striping increases the
request rate or the data-transfer rate.
IMPORTANT: While a storageset may be initialized with a user-selected chunk
size, it is recommended that only the default value be used. The default value is
chosen to produce optimal performance for a wide variety of loads. The use of a
chunk size less than 128 blocks (64K) is strongly discouraged. There are
almost no customer loads for which small chunk sizes are of value and, in almost
all cases, selecting a small chunk size will severely degrade the performance of
the storageset and the controller as a whole. Use of a small chunk size on any
storageset can result in severe degradation of overall system performance.
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
3–51

Advertisement

Table of Contents
loading

Table of Contents

Save PDF