4–24
Configuring Storagesets
The following modes can be assigned:
A—DIGITAL UNIX
B—IBM AIX
C—HSZ15
D—Windows NT
E—Silicon Graphics Inc. IRIX
F—Sun Solaris
For more information on the modes, see "SET controller," page 5–91. To view the
host mode setting on the controller, use the following syntax:
SHOW THIS_CONTROLLER FULL
or
SHOW OTHER_CONTROLLER FULL
To set the host mode, use one of the following syntax:
SET THIS_CONTROLLER HOST_FUNCTION = (ID, MODE)
or
SET OTHER_CONTROLLER HOST_FUNCTION = (ID, MODE)
Example
In Figure 4–1, two different hosts are connected on the same SCSI host bus going into
Port 1 of a shared controller. Targets 0 and 1 (units D0–D2, D100–D102) are
configured in DIGITAL Open VMS mode and targets 2 and 3 (D200–D202 and
D300–D302) are configured in Windows NT Server mode. Because the default host
mode includes DIGITAL Open VMS in Host Mode A, all of the targets are
automatically assigned to Host Mode A.
®
, OpenVMS, and Hewlett-Packard
®
TM
Server
®
HP–UX (Default)