Delete Failedset - Compaq StorageWorks HSZ80 Configuration And Cli Reference Manual

Array controller acs version 8.3
Hide thumbs Also See for StorageWorks HSZ80:
Table of Contents

Advertisement

5–53

DELETE FAILEDSET

Removes a disk drive from the failedset. The failedset contains disk drives removed
by the controller from RAIDsets and mirrorsets because they failed or were manually
removed using the SET command. Enter the DELETE FAILEDSET command before
physically removing failed members from the storage shelf for testing, repair, or
replacement.
You should consider defective all disk drives in the failedset. Repair or replace disks
found in the failedset.
Syntax
DELETE FAILEDSET disk-name
Parameter
disk-name
Identifies the disk you want to delete from the failedset. Only one disk at a time can
be removed from a failedset.
Example
This example shows how to delete DISK20200 from the failedset:
DELETE FAILEDSET DISK20200
See also
SET FAILEDSET
SHOW FAILEDSET
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide