SCSI ID 7
Digital
UNIX
Controller
device bus
D100
Figure 4–3. Accessing Units with the Host Port's SCSI ID Number
To assign the units to one host using SCSI ID numbers, yet restrict the other host's
access, use the following syntax:
SET D100 DISABLE_ACCESS_PATH = ALL
SET D100 ENABLE_ACCESS_PATH = 7
SET D101 DISABLE_ACCESS_PATH = ALL
SET D101 ENABLE_ACCESS_PATH = 7
SET D102 DISABLE_ACCESS_PATH = ALL
SET D102 ENABLE_ACCESS_PATH = 6
SET D103 DISABLE_ACCESS_PATH = ALL
SET D103 ENABLE_ACCESS_PATH = 6
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
Host bus
Port 1
Port 2
HSZ80
Controller
device bus
D102
D101
D103