5–25
Examples
This example shows how to create a stripeset named STRIPE1 with three disks:
DISK10000, DISK20100, and DISK30200:
ADD DISK DISK10000 1 0 0
ADD DISK DISK20100 2 1 0
ADD DISK DISK30200 3 2 0
ADD STRIPESET STRIPE1 DISK10000 DISK20100 DISK30200
This example show how to create a stripeset named STRIPE1 and then create a
logical unit from it:
INITIALIZE STRIPE1
ADD UNIT D103 STRIPE1
This example shows how to create a two-member striped mirrorset (a stripeset whose
members are mirrorsets), and how to create a logical unit from it. Because you can
initialize the stripeset, you do not need to individually initialize the mirrorsets.
ADD DISK DISK10000 1 0 0
ADD DISK DISK20100 2 1 0
ADD DISK DISK30200 3 2 0
ADD DISK DISK40300 4 3 0
ADD MIRRORSET MR1 DISK10000 DISK20100
ADD MIRRORSET MR2 DISK30200 DISK40300
ADD STRIPESET STRIPE1 MR1 MR2
INITIALIZE STRIPE1
ADD UNIT D104 STRIPE1