Set Failedset - Compaq StorageWorks HSZ80 Configuration And Cli Reference Manual

Array controller acs version 8.3
Hide thumbs Also See for StorageWorks HSZ80:
Table of Contents

Advertisement

5–108
CLI Commands

SET FAILEDSET

Changes the automatic replacement policy for the failedset.
Syntax
SET FAILEDSET
Switches
AUTOSPARE
NOAUTOSPARE
Specifies the policy to be used by the controller when a disk drive is physically
replaced in the failedset.
Specify AUTOSPARE to instruct the controller to automatically move devices
physically replaced in the failedset into the spareset. Disks set to REMOTE cannot be
autospared.
Specify NOAUTOSPARE to instruct the controller to leave devices physically
replaced in the failedset. The device, though replaced, remains in the failedset until it
is manually removed with the DELETE FAILEDSET command.
In most circumstances, a disk physically replaced into the failedset is functional and
contains no metadata—that is, a new, initialized device. If you specify the
AUTOSPARE switch when a disk is physically replaced in the failedset, the
controller checks to see if any metadata is present. If the controller detects metadata,
the disk remains in the failedset. If the controller does not detect metadata, the
controller automatically initializes the disk and moves it from the failedset to the
spareset. Now a member of the spareset, the disk is available for any mirrorset or
RAIDset requiring a replacement member. If the automatic initialization fails, the
disk remains in the failedset.