When rebuilding is already started or
the logical drive is being rebuilt by a
Local Spare Drive or Global Spare
Drive, choose "Rebuild Progress" to
see the rebuild progress.
The Rebuild function will appear only if a logical drive (with RAID level 1,
3 or 5) has a failed member.
Use the "Identify Drive" function to check the exact location of a failed
drive. Removing the wrong drive may cause a logical drive to fail and data
loss is unrecoverable.

Regenerating Logical Drive Parity

If no verifying method is applied to data writes, this function can be
manually performed to ensure that parity errors can be mended.
From the Main Menu, press
select "View and Edit Logical Drives."
If you have more than one logical drive,
use the
you would like to check the parity for;
and then press ENT.
Press
and then press ENT.
To stop the regeneration process, press
ESC and enter the submenu to select
"Abort Regenerate Parity".
If Parity Regenerating process is stopped by a drive failure, the process
cannot restart until the logical drive is rebuilt.
5-19
IMPORTANT!
or
to select the logical drive
or
to select "Regenerate Parity"
IMPORTANT!
LG0 RAID5 DRV=3
2012MB RB SB=0
Rebuild Progress
or
to
View and Edit
Logical Drives
LG0 RAID5 DRV=3
4095MB GD SB=0
Regenerate
Parity
Abort Regenerate
Parity
..
..
..