2-Line LCD
C=_ I=_ Unexpected Sense Rec.
Terminal
[1115] CHL:_ ID:_ SCSI Drive ALERT: Unexpected Sense Received
(Sense_key Sense_code)
Event Type
What
Drive-side SCSI drive unexpected sense data received.
Happens?
What to
Checking drive-side cabling/termination/drive canister connections.
Do?
This might result from a bad signal quality of poor connection, etc.
2-Line LCD
C=_ I=_ Block Reassign Failed
Terminal
[1116] CHL:_ ID:_ SCSI Drive ALERT: Block Reassignment Failed -
Block_number (Sense_key Sense_code)
Event Type
What
Drive-side block reassignment failed. Drive will be considered failed.
Happens?
What to
Press [ESC] to clear this error message.
Do?
2-Line LCD
C=_ I=_ Block Success Reassign
Terminal
[1117] CHL:_ ID:_ SCSI Drive ALERT: Block Successfully Reassigned –
Block_number (Sense_key Sense_code)
Event Type
What
Bad blocks have been reassigned successfully
Happens?
What to
Press [ESC] to clear this message.
Do?
2-Line LCD
CHL=_ ID=_ Aborted Command
Terminal
[1118] CHL:_ ID:_ SCSI Drive ALERT: Aborted Command (Sense_key
Sense_code)
Event Type
What
SCSI drive aborted command reported
Happens?
What to
Press [ESC] to clear the error message.
Do?
Event Messages
"Alert
!Warning
"Alert
!Warning
"Alert
"Warning
"Alert
!Warning
"Notification
"Notification
!Notification
"Notification
D-13
Need help?
Do you have a question about the External RAID Controller & Subsystem Infortrend and is the answer not in the manual?