6.6
SCSI Drive Status
6-6
Slot
Slot number of the drive;
"S" indicates this is the drive used for passing through SES
signals
Chl
The drive channel where the drive is connected
X<Y> indicates two channels are configured in a dual-loop
ID
The channel ID assigned to this drive
Size (MB)
Drive capacity
Speed
XxMB Maximum transfer rate of drive channel interface
Async The drive is using asynchronous mode.
LG_DRV
X
Status
Global
INITING
ON-LINE
REBUILD
STAND-BY
NEW DRV
USED DRV
BAD
ABSENT
MISSING
SB-MISS
Vendor and
Product ID
The drive is a drive member of logical drive x.
If the Status column shows "STAND-BY", the drive
is a Local Spare of logical drive x.
The SCSI drive is a Global Spare Drive
Processing array initialization
The drive is in good condition
Processing Rebuild
Local Spare Drive or Global Spare Drive. The
Local Spare Drive's LG_DRV column will show
the logical drive number. The Global Spare
Drive's LG_DRV column will show "Global".
A new drive has not been configured to any
logical drive or as a spare drive
An used drive that is not a member of any
logical drive or configured as spare
Failed drive
Drive does not exist
Drive once existed, but is missing now
Spare drive missing
The vendor and product model information of
the drive
Infortrend
Need help?
Do you have a question about the External RAID Controller & Subsystem Infortrend and is the answer not in the manual?