Scsi Drive Read/Write Test - Compaq External RAID Controller & Subsystem Infortrend Operation Manual

Compaq external raid controller & subsystem operation manual
Table of Contents

Advertisement

SCSI Drive Read/Write Test

From the "View and Edit SCSI Drives" menu, select a new or used
drive that the utility is to perform on; then press [ENTER]. Select
"SCSI Drive Utilities," then press [ENTER]. Choose "Read/Write
Test" and press [ENTER]. You can choose to enable/disable the
following options:
1.
2.
3.
When finished with configuration, select "Execute Drive Testing"
and press [ENTER] to proceed.
The Read/Write test progress will be indicated by a status bar.
You may press [ESC] and select "Read/Write Test" later and choose
either to "View Read/Write Testing Progress" or to "List Current
Bad Block Table."
"Abort Drive Testing" and press [ENTER] to proceed.
Terminal Operation
Auto Reassign Bad Block;
Abort When Error Occurs;
Drive Test for - Read Only/Read and Write.
If you want to stop testing the drive, select