Compaq External RAID Controller & Subsystem Infortrend Operation Manual page 338

Compaq external raid controller & subsystem operation manual
Table of Contents

Advertisement

SES Device:
Alert:
2-Line LCD
Power Supply_ Failure Detected
Terminal
[3f21] SES (C_I_) Power Supply_: Power Supply Failure Detected
Event Type
What
Power supply failure detected.
Happens?
What to
Check power module status and contact your supplier for a
Do?
replacement unit.
2-Line LCD
Cooling Fan_ Not Installed
Terminal
[3f22] SES (C_I_) Cooling element_: Cooling Fan Not Installed
Event Type
What
Cooling fan missing or not detected.
Happens?
What to
Check proper fan installation or contact your supplier to replace a
Do?
failed unit.
2-Line LCD
Cooling Fan_ Failure Detected
Terminal
[3f22] SES (C_I_) Cooling element_: Cooling Fan Failure Detected
Event Type
What
Contact your system provider for an immediate replacement of fan
Happens?
modules.
What to
Contact your system provider for an immediate replacement of fan
Do?
modules.
2-Line LCD
C_I_: Elevated Temperature Alert
Terminal
[3f23] SES (C_I_) Temperature Sensor_: Elevated Temperature Alert
Event Type
What
Detected temperature exceeding safety range.
Happens?
What to
Check cooling fan status. Contact your system provider for an
Do?
immediate replacement of fan modules.
2-Line LCD
UPS Power Failure Detected
Terminal
[3f24] SES (C_I_) UPS_: UPS Power Failure Detected
Event Type
What
UPS power failure detected.
Happens?
What to
Check UPS status. If power should fail and UPS is not able to sustain
Do?
power, data loss might occur.
D-38
!Alert
"Warning
!Alert
"Warning
!Alert
"Warning
!Alert
"Warning
!Alert
"Warning
" Notification
" Notification
" Notification
" Notification
" Notification
Infortrend

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the External RAID Controller & Subsystem Infortrend and is the answer not in the manual?

Table of Contents

Save PDF