Warning:
2-Line LCD
LG ALERT: Init Failed!
Terminal
[2102] LG:_ Logical Drive ALERT: Initialization Failed
Event Type
What
Logical drive initialization failed. It could result from one of the
Happens?
following reasons:
1. Logical drive initialization canceled by user.
2. On of the member drives failed during logical drive initialization.
3. One of the member drive encountered bad block.
What to
Carefully identify and replace the faulty drive and let the logical drive
Do?
re-initialize and start rebuild.
2-Line LCD
LG=_ Parity Regen Failed !
Terminal
[2104] LG_ Logical Drive ALERT: Parity Regeneration Failed
Event Type
What
During the parity-regeneration process, one member drive has failed.
Happens?
What to
Rebuild the logical drive first, then perform "Regenerate Parity."
Do?
Regeneration can only be performed on a "Good" (GD) logical drive.
2-Line LCD
C:_ I:_ Clone Failed!
Terminal
[2111] LG_ Logical Drive ALERT: CHL:_ ID:_ Clone Failed
Event Type
What
The clone drive operation has failed or halted by system error.
Happens?
What to
One of the member drives might have failed during the process.
Do?
Replace the faulty drive and let the system rebuild. Data on the source
drive (from where the spare clone data) may still be intact. Locate and
replace the faulty drive and rebuild.
Notification:
2-Line LCD
LG=_ Starting Init
Terminal
[2181] LG_ Logical Drive NOTICE: Starting Initialization
Event Type
What
The controller starts initialize the logical drive.
Happens?
What to
Press <ESC> to clear the message.
Do?
2-Line LCD
LG=_ Initialization Completed!
Terminal
[2182] Initialization of Logical Drive_ Completed
Event Type
What
The initialization process of LG_ has been completed.
Happens?
What to
Press <ESC> to clear the message. See if host computer can recognize
Do?
the RAID drive.
2-Line LCD
LG=_ Starting Rebuild !
D-18