Rebuilding A Logical Drive - Compaq External RAID Controller & Subsystem Infortrend Operation Manual

Compaq external raid controller & subsystem operation manual
Table of Contents

Advertisement

example, when one or more logical drives have been deleted, the
array indexing is changed after system reboot. The second logical
drive might become the first on the list.
Choose the logical drive you wish to assign a name, then press
[ENTER]. Choose "logical drive name," then press [ENTER] again.
The current name will be displayed. You may now enter a new
name in this field. Enter a name, then press [ENTER] to save the
configuration.

Rebuilding a Logical Drive

If there is no spare drive in the system, a failed drive should be
immediately replaced by a drive known to be good. Once the failed
drive is replaced, the rebuild process can be manually initiated.
If you want the controller to auto-detect a replacement drive, make
sure you have the following items set to enabled:
1.
2.
These two configuration options can be found under "View and Edit
Configuration Parameters" -> " Drive-Side SCSI Parameters".
Choose the logical drive that has a failed member drive, then press
[ENTER]. Choose "Rebuild logical drive", then press [ENTER].
When prompted to "Rebuild Logical Drive?," select Yes.
The rebuild progress will be displayed.