Enter a hex number from 0 to FFFFF and press
[ENTER].
different for each controller.
Power off controller 1, then power on controller 2.
Set controller 2 to "Secondary" as described
above.
Power off controller 2.
Starting the Redundant Controllers
Power on all hard drives and the two controllers.
If drives are installed in a drive enclosure, wait
for the drives to be ready, then power on the
enclosure where the RAID controllers are
installed.
The
connecting... <ENT> to cancel" will appear on the
LCD display of the two controllers. After a few
seconds, the Primary controller will startup with
the
displayed on the LCD, while the Secondary
controller will display the message "RC Standing
By.. <ENT> to Cancel" on its LCD. A few seconds
later, the LCD display on the Secondary
controller will be similar to the LCD display on
the Primary controller. The upper right corner of
LCD will then be displaying a "P" or "S,"
meaning "Primary" or "Secondary" respectively.
During normal operation, the controllers continuously monitor each other.
Each controller is always ready to take over for the other controller in an
unlikely event of a controller failure.
The Primary and Secondary controllers synchronize each other's
configurations at frequent intervals through the communications channel(s).
Creating Primary and Secondary ID
Drive Channel
Enter "View and Edit SCSI Channels."
[ENT] and use
channel
Primary/Secondary IDs.
Press [ENT] to proceed.
Use
ID .." or " "Set SCSI Channel Sec. Ctlr ID ..." Press
[ENT] to proceed.
10-22
The value you enter should be
message
"RC
(redundant
model
number
and
or
to select the host or drive
on
which
you
or
to select "Set SCSI Channel Pri. Ctlr
controller)
firmware
version
Press
wish
to
create
RC connecting...
<ENT> to cancel
View and Edit
SCSI Channels
CH1=Drive PID=7
SID=NA SXF=80.0M
Set SCSI Channel
Sec. Ctlr ID ..
Infortrend
Need help?
Do you have a question about the External RAID Controller & Subsystem Infortrend and is the answer not in the manual?