3.2.3
NPC is short for Notification Processing Center, a sub-module for
use with system event notification.
To activate the NPC module, do the following:
1.
2.
3.
Listed below is the sample configuration.
configuration using simple defining parameters as shown below.
The configuration file is comprised of three major sections: SNMP, Email
and Broadcast.
disabled.
Connecting Terminal
NPC Onboard
Create an NPC configuration file (in a simple text file format)
using a text editor program.
Save it in the name of "agent.ini"
FTP it to the controller IP address, and then reset the controller
for the configuration to take effect.
[SNMP_TRAP]
ENABLED=0
(1=on; 0=off)
SEVERITY=1
COMMUNITY=public
RECEIVER1=XXX.XXX.XXX.XXX,2 ("2" specifies the level of
[EMAIL]
ENABLED=0
SEVERITY=1
SUBJECT=Event Message
SENDER_MAIL_BOX=XXXX@XXXXX.XXX
SMTP_SERVER=XXX.XXX.XXX.XXX
RECEIVER1=XXXX@XXXXX.XXX,3
RECEIVER2=XXXX@XXXXX.XXX,1
RECEIVER3=XXXX@XXXXX.XXX,2
RECEIVER4=XXXX@XXXXX.XXX,1
[BROADCAST]
ENABLED=0
SEVERITY=1
RECEIVER=XXX.XXX.XXX.XXX, 1
RECEIVER=XXX.XXX.XXX.XXX, 1
NOTE:
NPC will be automatically activated if any of the notifier settings
(email, SNMP, or broadcast) is set to "enabled."
Each notifying method can be separately enabled or
events to be received by this receiver)
Specify your
3-9
Need help?