MAX II Bolt Tension Monitor
4.7 GATES – Menu
POLARITY: The MAX II operates on a zero crossing detection principal. This
feature toggles which stroke of the cycle the crossing detection uses, either positive
or negative. Refer to page 147 for further info.
GATE 1: Gates allow the user to view a specific measurement range, or sections of
the waveform, and ignore others. The Gate1 feature adjusts the start of the gate,
according to time/distance. Gate 1 can be used in all pulse-echo and echo-echo
measurement modes. Refer to page 120 for further info.
THRESHOLD1: Enables the user to set the sensitivity level of Gate1. The amplitude
of the signal must reach or exceed the threshold level before a measurement is
detected. Refer to page 120 for further info.
GATE 2: Provides the user with the ability to delay the starting point of Gate2, a
specific distance from the first detection point found inside of the boundaries of the
Gate 1 settings. If no detection is found, the Gate1 width value is used as a starting
value for Gate2. Refer to page 120 for further info.
THRESHOLD2: Enables the user to set the sensitivity level of Gate2. The amplitude
of the signal must reach or exceed the threshold level before a measurement is
detected. Refer to page 120 for further info.
GATE 3: Provides the user with the ability to delay the starting point of Gate3, a
specific distance from the first detection point found inside of the boundaries of the
Gate 2 settings. If no detection is found, the Gate2 width value is used as a starting
value for Gate3. Refer to page 120 for further info.
THRESHOLD3: Enables the user to set the sensitivity level of Gate3. The amplitude
of the signal must reach or exceed the threshold level before a measurement is
detected. Refer to page 120 for further info.