Analog Output - DAKOTA ULTRASONICS MAX II Operation Manual

Ultrasonic bolt tension monitor
Hide thumbs Also See for MAX II:
Table of Contents

Advertisement

Dakota Ultrasonics
3) Press the
right button wheel to scroll the highlighted value.
4) Press the
right button wheel to scroll the digit locations.
5) Repeat steps 3 & 4 until the ALARM LOW value is correctly displayed.
6) If only one limit will be used, press the MEAS key to return to the
measurement screen and begin taking readings. Otherwise, repeat the
steps outlined above to set the ALARM HIGH limit.

13.13 Analog Output

The MAX II is also equipped with an analog output to send a 0-10 volt electrical
signal to an external device to control a system process to respond in a different
manner considering the voltage measured. The outputs are updated at the same
rate as the PRF (pulse repetition frequency) setting. There is 100 ohm output
impedance which will vary the voltage slightly and should therefore be calibrated to
the device connected. The output options are amplitude or distance. Refer to the
Top & Bottom end caps or connections on page 38 for further info on the pins used
on the Lemo 1 5 pin connector. The procedures for activating and selecting
amplitude or distance are outlined below:
1) Press the MENU key once to activate the menu items tab. Press the MENU
key multiple times to tab right and the ESC key multiple times to tab left until
Find Quality Products Online at:
UP and DOWN arrow keys multiple times using the left or
LEFT and RIGHT arrow keys multiple times using the left or
Activating Analog Out
150