Output Items (Out1 To Out3) - Fastus LS Series User Manual

2d displacement sensor
Table of Contents

Advertisement

Output
3.5.1

Output Items (OUT1 to OUT3)

When the OUT1, OUT2, or OUT3 tab is selected, you can use the output display settings to configure the following items.
Setting item Bank Setting value/default value
Out target
Y
Select the area or calculation to set as the output target.
Area1
Area2
Area3
Area4
Calc1
Calc2
Upper limit
Y
Set the upper limit of control output.
-32.766 to +32.767 [+25.000]
Lower limit
Y
Set the lower limit of control output.
-32.767 to +32.766 [-25.000]
Out action
Y
Select the operation to perform during output.
Normal
1shot
OnDelay
Ready
Strobe
1shot2
Out polar
Y
Select the polarity to use for output (when "On Timing" is set to "Out range".)
N.O.
N.C.
Output time
Y
Set the output time.
The condition to enable this function is: Out action: 1shot, OnDelay, Strobe or 1shot2.
0.1 to 204.7 [0.1]
Offset value
Y
Set an offset value (value to be added) to the output result display.
When the external input "Offset" setting is set to "ON," this offset value will be displayed.
-327.67 to +327.67 [0.00]
Hysteresis
Y
To prevent chattering, set the amount that the value can fall below (or exceed) the threshold
before the output state changes from the state outside the range specified by the thresholds.
0 / 4 / 8 / 16 / 32 / 50 / 75
/ 100 / 150 / 200 / 300 /
500 / 750 / 1000 / 1500
/2000 [0]
Offset
Y
A value will be added to or subtracted from the measured value so that the display value equals
the "Offset value" setting.
For example, if the offset value is "0," the display will be "0" when the offset operation is performed.
When measurement is not possible, offset input will be ignored.
OFF
ON
Reference
For details on the output display settings, see "5.8 Output Settings."
3-20
Ramco National
The measured result of area 1 will be output.
The measured result of area 2 will be output.
The measured result of area 3 will be output.
The measured result of area 4 will be output.
The result of calculation 1 will be output.
The result of calculation 2 will be output.
* The unit varies depending on the measurement function.
* The displayed value includes the "Offset value" setting.
* The unit varies depending on the measurement function.
* The displayed value includes the "Offset value" setting.
The normal on/off output will be performed.
Each time that output is turned on, one-shot output will
be performed.
When the output is turned on, output will be performed
after a delay elapses.
When trigger input is possible, output will be performed.
When the measured value is updated, one-shot output
will be performed.
When output goes from off to on, one-shot output will be
performed.
When the measurement result exceeds the upper limit or
lower limit, the output will be closed state.
Output turns to open state in the trigger standby state.
When the measurement result exceeds the upper limit or
lower limit, the output will be ovvpen state.
Output turns to closed state in the trigger standby state.
[Unit: ms] * You can set this value in steps of 0.1 ms.
* The unit varies depending on the measurement function.
* You can set this value in steps that are 10 times the value of
the minimum display digit.
* The unit varies depending on the measurement function.
The offset will be cleared.
The offset operation will be performed.