Output Settings - Fastus LS Series User Manual

2d displacement sensor
Table of Contents

Advertisement

4.4.7

Output Settings

This section explains the details of the output setup screen.
Reference
For details on the output settings, see "5.8 Output Settings."
(1)
(2)
Number Display item
Displays the measured
Output
(1)
results of outputs 1, 2,
values
and 3.
Displays the current
(2)
Analog Out
value of analog output.
Executes the offset on/
(3)
OFFSET
clear from the specified
output (output 1, 2, or 3).
Detailed
Displays the detailed
(4)
output
output settings of the
settings
target.
Detailed
analog
Configure the detailed
(5)
output
analog output settings.
settings
Enters the current
Current
(6)
measured value into the
Displ.
specified item.
Click to write parameters
(7)
Write Param
to the LS.
Ramco National
(3)
(5)
Description
Displays the measured results of the target outputs.
Click an output to display its detailed settings (4). The
currently selected output is displayed in light blue.
Displays the measured result of the analog current output .
DIsplays the analog output current and measured value.
Execute the offset to set the current measured value to the
value set with "Offset" in the detailed output settings (4).
(Example: If "Offset" is set to "0.000," the current value will
become "0.")
Displays the detailed settings of the output selected with
(1).
You can change settings by selecting and typing values.
Displays the setting values in the input boxes.
Click to enter the current measured value in the target
item.
Click to write the setting details to the LS.
(The same operation is performed as when you click "Write
Param" in the upper left of the screen.)
800-280-6933 | nsales@ramcoi.com
(4)
Operation
Setup Procedure
(6)
(7)
4-23
www.Optex-Ramco.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ls-100cnLs-100cp

Table of Contents