Displacement sensor
CD22 Series
CD22-15
CD22M-15
CD22-35
CD22M-15
CD22-100
CD22M-100
Instruction manual
- Thank you for purchasing CD22 series. We hope you are satisfi  ed with its performance.
- Please read this manual carefully and keep it for future reference.
Indicates a  possible hazard that may  result in death, serious 
injury, WARNINGS or serious property damage if the product is 
used without observing the stated instructions.
Warning       Mandatory Requirements
● The light source of this product applies the visible light semiconductor laser. Do not 
allow the laser beam to enter an eye, either directly or refl  ected from refl  ective object. If 
the laser beam enters an eye, it may cause blindness.
● This product is not an explosion proof construction. Do not use the product under fl  am-
mable , explosive gas or liquid environment.
● Do not disassemble or modify the product since it is not designed to automatically stop 
the laser emission when open. Disassembling or modifying at customer's end it may 
cause personal injury, fi  re or electric shock.
●Use of controls or adjustments or performance of procedures other than those specifi  ed 
herein may result in hazardous radiation exposure.
 
Warning     Safety Precautions
● It is dangerous to wire or attach/remove the connector while the power is on. Make sure 
to turn off   the power before operation.
● Installing in the following places may result in malfunction:
 
1. A dusty or steamy place
 
2. A place generating corrosive gas
 
3. A place directly receiving scattering water or oil.
 
4. A place suff  ered from heavy vibration or impact.
● The product is not designed for outdoor use.
● Do not use the sensor in a transient state at power on (Approx. 15min. Warm up period)
● Do not wire with the high voltage cable or the power lines.  Failure to do this will cause 
malfunction by induction or damage.
● Do not use the product in water.
● Operate within the rated range.
● Wipe 
off   dirt on the emitting/receiving parts to maintain correct detection. Also, avoid 
direct impact on the product.
● Don't bend the cable when the temperature of the cable or atmosphere is below freezing.
Precautions for using laser
● Regulations in the USA
When exporting laser devices to the USA, the USA laser control, FDA
(Food and Drug Administration) is applied. This product has been already
reported to CDRH (Center for Devices and Radiological Health). For
details, contact our customer service.
・Laser WARNING label
・FDA Certifi  cation label
Laser diode
Wave length:655nm, Max output:10mW,//9 degree type.
Bundled goods in the box
Please confi  rm following goods bundled in the box.
・CD22 -
・This instruction manual
・Screws
M3 × 15...2
Connection diagram
Specifi  cations
Setup
Displacement sensor
CD22 Series
■ NPN type
● Part number legend
● Changing mode
to "Measurement mode" by pressing "ZERO/RUN" button.
While it's "Teach mode", "Setup mode" or "Extension mode", you can change the mode 
CD22-15
CD22-35
CD22M-15
CD22M-15
Brown : +V
DC 12~24V
10%
While it's "Setup mode" or "Extension mode", the LED "MANUAL" is lit.
CD22-100
- Thank you for purchasing CD22 series. We hope you are satisfi  ed with its performance.
CD22M-100
Instruction manual
3.3V
: External input
- Please read this manual carefully and keep it for future reference.
Indicates a  possible  hazard that may result in  death, serious 
number
● Specifi cations per measurement range
Part 
SUS housing
Aluminum housing
CD22-15
CD22M-15
CD22-35
CD22M-35
CD22M-100
CD22-100
used without observing the stated instructions.
injury, WARNINGS or serious property damage if the product is 
* : M8 connector type doesn't have
: 0V / Analog GND
Light source
Measurement range
Center of measurement range
Max. output: 390 µW
±5mm
15mm
Red laser Diode (wave length 655nm)
35mm
±15mm
100mm
±50mm
allow the laser beam to enter an eye, either directly or refl  ected from refl  ective object. If 
● The light source of this product applies the visible light semiconductor laser. Do not 
Warning       Mandatory Requirements
■ PNP type
Brown : +V
DC 12~24V
10%
Laser
class
Spot size
※ 1
IEC/JIS
500 * 700µm
Suffi x nul: CLASS 1 / 2: CLASS 2 (Laser Notice No.50)
450 * 800µm
600 * 700µm
Max. output: 1mW
※ 3
mable , explosive gas or liquid environment.
the laser beam enters an eye, it may cause blindness.
● This product is not an explosion proof construction. Do not use the product under fl  am-
● Do not disassemble or modify the product since it is not designed to automatically stop 
: : External input
Temperature drift (typical value)
Sampling period
Repeatability
Linearity
※ 2
±0.02% / ℃ of F.S.
500µs / 1000µs / 2000µs / 4000µs / AUTO
1µm
0.1% of F.S.
0.1% of F.S.
±0.02% / ℃ of F.S.
6µm
20µm
±0.05% / ℃ of F.S.
0.1% of F.S.
● Changing parameters
You can choose and adjust the parameters by pressing "+" and "-" buttons.
herein may result in hazardous radiation exposure.
●Use of controls or adjustments or performance of procedures other than those specifi  ed 
cause personal injury, fi  re or electric shock.
the laser emission when open. Disassembling or modifying at customer's end it may 
Control Output
External Input
Indicator
Output indicator: Orange / Mode indicator: Red
Laser indicator: Green / Zero reset indicator: Red
Laser OFF, Teaching, Sample & Hold, One shot, Zero reset
NPN/PNP max.100mA/DC30V ((Residual voltage 1.8 V max.)
The mode will be changed to "Measurement mode" by pressing "ZERO/RUN" button.
 
Warning     Safety Precautions
: 0V / Analog GND
* : M8 connector type doesn't have
Operating Temp./Humid.
Protection circuit
Current consumption
Protection category
70mA max. including Analog output current
-10 ~ 50℃ / 35 ~ 85% RH without freasing or condensation
Reverse connection protection, Over current protection
IP67 including connection part
to turn off   the power before operation.
 
● It is dangerous to wire or attach/remove the connector while the power is on. Make sure 
● Installing in the following places may result in malfunction:
1. A dusty or steamy place
    ( sensor side )
■ Pins confi  guration
・  M12 type
・  M8 type
Shock resistence
Vibration resistence
Ambient illuminance
Storage Temp./Humid.
10 ~ 55Hz, Double amplitude 1.5mm, X,Y,Z for 2 hours
500mm/s
-20 ~ 60℃ / 35 ~ 85%/RH
( approx. 50G) X,Y,Z 3 times each
2
Incandescent lamp: 3,000 lx max.
 
● The product is not designed for outdoor use.
 
 
4. A place suff  ered from heavy vibration or impact.
3. A place directly receiving scattering water or oil.
2. A place generating corrosive gas
Material
Weight
Case: Aluminum/SUS316L, Front lens: PPSU, Display: PET
Aluminum case with M12 connector : Approx. 60g including
SUS case with M12 connector type : Approx. 90g including
300mm cable with connector
300mm cable with connector
Teach mode
● Do not wire with the high voltage cable or the power lines.  Failure to do this will cause 
● Do not use the sensor in a transient state at power on (Approx. 15min. Warm up period)
malfunction by induction or damage.
● Do not use the product in water.
Dimensions
ply voltage: 24VDC, Sampling period: 500µs, Averaging: 64, Measuring distance: Center of the range, Testing 
The specifi  cations are based on the condition unless otherwise designated: Ambient temperature: 23℃ , Sup-
SUS case with M8 connector : Approx. 70g
Aluminum case with M8 connector : Approx. 40g
NEnu
direct impact on the product.
● Operate within the rated range.
● Wipe off   dirt on the emitting/receiving parts to maintain correct detection. Also, avoid 
■ M12 type
[mm]
※ 3  for Laser Class 2 type ( Model : CD22-100AM122 , CD22-100VM122 , CD22-100A2 , CD22-100V2)
※ 2  512 averaging time
※ 1  Defi  ned with center strength 1/e
spot size. The sensor may be aff  ected when there is a highly refl  ective object close to the detection area.
object: White ceramic
(13.5%) at the center. There may be leak light other than the specifi  ed 
2
NodE
1Pt
FGS2
Precautions for using laser
Type
● Specifi cations per output
Part number
CD22 -
Voltage output
V
CD22 -
Current output
A
CD22 -
RS-485 type
-485
2Pt
reported to CDRH (Center for Devices and Radiological Health). For
(Food and Drug Administration) is applied. This product has been already
When exporting laser devices to the USA, the USA laser control, FDA
● Regulations in the USA
Display
Output impedance
Power supply
Analog output range
Maximum load impedance
0 ~ 10V
※ 1
100
300
4 ~ 20mA
DC12-24V ±10%
※ 1
FGS2
tch
details, contact our customer service.
M12 5pin
※ 1 
Functions of components
 
Please keep power supply voltage over 12.0V for Voltage output type
to get 0-10V analog output correctly.
nEAr
tch
Connector
FAr
tch
・Laser WARNING label
■ M8 type
・Laser label [reserve]
Laser diode
Wave length:655nm, Max output:10mW,//9 degree type.
・FDA Certifi  cation label
Please confi  rm following goods bundled in the box.
Bundled goods in the box
Display
● Control panel
・CD22 -
・This instruction manual
M3 × 15...2
・Screws
・Laser label [reserve]
M8 4pin
Connector
Measurement mode
Setup mode
Miscellaneous function
Following output shows its ON/OFF status as "Light ON 
CD22 has 3 measurement mode. The mode is chosen by "Teach mode".
Output can be reversed by setting "Output polarity 
 ".
L on
Acti
 ".
Setup mode is chosen by pressing "SET" button from "Menu". (* means default value)
ALrN
hoLD
cLNP
Teaching is done at a position. When the measurement distance is closer than that position, the output 
● 1 point Teaching
will be ON.
10U
0. 1 23
hdct
0000
0. 0 00
FAr
0U
0. 1 23
hoLD
hYSt
20nA
0. 1 23
hdct
Teaching is done at 2 positions. While the measurement distance is between those positions, the out-
● 2 point Teaching
put will be ON.
4nA
0. 1 23
FAr
nEAr
YES
Loc
Loc
hYSt
hYSt
nEAr
0. 1 23
rESt
no
teresis 
Teaching is done at a position. When the measurement distance is closer than the distance set by "Hys-
● FGS2
 "from the position that Teaching is done, the output will be ON. It works as FGS sensor.
toL
FAr
0. 1 23
diSP
oFF
on
uLoc
toL
FGS2
Extension mode
FGS2
0. 1 23
Please use with default setting when changing parameters is not needed.  ( " * " means default setting)
Extension mode is chosen by pressing "+" and "-" buttons at a time for 1 second.
Parameters in Extension mode must be set correctly otherwise it might not work correctly.
hYSt
hYSt
NodE
FGS2
1Pt
hYSt
0 . 1 23
tance.
Analog Output
Analog Current or Analog Voltage type outputs Analog output according to the measurement dis-
toL
0. 1 23
2Pt
NtoP
NAH
The distance range for Analog output is set in Teaching mode or Setup mode.
Pt5
Pt3
Pt4
(approx. 15V)
approx. 24mA
inp
oFF
tch
LSr
Pt1
Pt2
S h
onE
thrE
P400
bASE
4nA
20nA
SANP
2Ero
500
P100
P200
ing so could lead to serious injury or death. These sensors do not include 
Attention: Not to be Used for Personnel Protection.
Never use these products as sensing devices for personnel protection. Do-
● Default value of each Analog output type
Current ( Voltage)
0U
CD22 -15
CD22 -35
10U
CD22 -100
4000
2000
1000
tout
off
100N
sonnel safety applications. A sensor failure or malfunction can cause either 
the self-checking redundant circuitry necessary to allow their use in per-
an energized or de-energized sensor output condition.
4nA
(
20nA
(
10U
0U
)
)
- 5.000
5.000
- 15.000
15.000
- 50.00
50.00
Auto
SaNp
ANSI and IEC standards for personnel protection.
Please consult our distributors about safety products which meet OSHA, 
Multiple function can be set at external input. When it's set as "Teaching" or "Zero reset", The function 
varies by input period as follows.
External Input
Acti
L on
D on
inct
1
      any obligations on the part of manufacture.
● Specifi  cations and equipment are subject to change without
■ Teaching
input period (sec.)
0 to 0.5 sec.
Do nothing
What to teach (Teaching current position)
n_P
nPn
2Ero
256
0 . 1 23
      products, please contact us below.
● For more information, questions and comments regarding
http://www.optex-fa.com/rohs_cn/
0.5 to 1.5 sec.
1.5 to 2.5 sec.
3.5 to 4.5 sec.
2.5 to 3.5 sec.
Near side threshold
Far side threshold
Current output type : 20mA/ Voltage output type 10V
Current output type : 4mA/ Voltage output type : 0V
PnP
■ Zero reset
over 4.5 sec.
input ( sampling )
FGS2 threshold
Function
AUG
1
64
8
SEnS
N__6
Auto
TEL : +81-(0)75-325-2920
91 Chudoji Awata-cho Shimogyo-ku Kyoto 600-8815 Japan
over 2,000
0 to 1,999
Zero reset
Release Zero reset
512
N__1
Website : http://www.optex-fa.com
FAX: +81-(0)75-325-2921
Measurement mode
CD22 has 3 measurement mode. The mode is chosen by "Teach mode".
Output can be reversed by setting "Output polarity 
 ".
Acti
Following output shows its ON/OFF status as "Light ON 
 ".
L on
● 1 point Teaching
Teaching is done at a position. When the measurement distance is closer than that position, the output 
will be ON.
FAr
hYSt
● 2 point Teaching
Teaching is done at 2 positions. While the measurement distance is between those positions, the out-
put will be ON.
FAr
nEAr
hYSt
hYSt
● FGS2
Teaching is done at a position. When the measurement distance is closer than the distance set by "Hys-
teresis 
 "from the position that Teaching is done, the output will be ON. It works as FGS sensor.
toL
FGS2
toL
hYSt
hYSt
Analog Output
Analog Current or Analog Voltage type outputs Analog output according to the measurement dis-
tance.
The distance range for Analog output is set in Teaching mode or Setup mode.
approx. 24mA
(approx. 15V)
4nA
20nA
0U
10U
● Default value of each Analog output type
Current ( Voltage)
CD22 -15
CD22 -35
CD22 -100
(
)
- 5.000
- 15.000
4nA
0U
(
)
5.000
15.000
20nA
10U
External Input
Multiple function can be set at external input. When it's set as "Teaching" or "Zero reset", The function 
varies by input period as follows.
■ Teaching
input period (sec.)
What to teach (Teaching current position)
0 to 0.5 sec.
Do nothing
0.5 to 1.5 sec.
Current output type : 4mA/ Voltage output type : 0V
1.5 to 2.5 sec.
Current output type : 20mA/ Voltage output type 10V
2.5 to 3.5 sec.
Near side threshold
3.5 to 4.5 sec.
Far side threshold
over 4.5 sec.
FGS2 threshold
■ Zero reset
input ( sampling )
Function
0 to 1,999
Zero reset
over 2,000
Release Zero reset
Connection diagram
■ NPN type
Brown : +V
3.3V
: External input
: 0V / Analog GND
* : M8 connector type doesn't have
■ PNP type
Brown : +V
: : External input
: 0V / Analog GND
* : M8 connector type doesn't have
■ Pins confi  guration
・  M12 type
    ( sensor side )
Dimensions
■ M12 type
■ M8 type
Setup mode
Setup mode is chosen by pressing "SET" button from "Menu". (* means default value)
10U
0. 1 23
0. 1 23
0U
20nA
0. 1 23
4nA
0. 1 23
0. 1 23
nEAr
FAr
0. 1 23
FGS2
0. 1 23
NodE
1Pt
FGS2
2Pt
toL
0. 1 23
inp
oFF
LSr
tch
S h
onE
2Ero
SANP
500
1000
2000
4000
- 50.00
Auto
50.00
L on
Acti
D on
nPn
n_P
PnP
AUG
1
8
64
512
Specifi  cations
● Part number legend
DC 12~24V
10%
● Specifi cations per measurement range
Aluminum housing
Part 
number
SUS housing
Center of measurement range
Measurement range
Light source
Laser
IEC/JIS
class
DC 12~24V
10%
※ 1
Spot size
Linearity
Repeatability
※ 2
Sampling period
Temperature drift (typical value)
Indicator
External Input
Control Output
Current consumption
Protection circuit
Protection category
Operating Temp./Humid.
Storage Temp./Humid.
・  M8 type
Ambient illuminance
Vibration resistence
Shock resistence
Material
Weight
The specifi  cations are based on the condition unless otherwise designated: Ambient temperature: 23℃ , Sup-
ply voltage: 24VDC, Sampling period: 500µs, Averaging: 64, Measuring distance: Center of the range, Testing 
object: White ceramic
[mm]
※ 1  Defi  ned with center strength 1/e
spot size. The sensor may be aff  ected when there is a highly refl  ective object close to the detection area.
※ 2  512 averaging time
※ 3  for Laser Class 2 type ( Model : CD22-100AM122 , CD22-100VM122 , CD22-100A2 , CD22-100V2)
● Specifi cations per output
Part number
Type
Display
Analog output range
Maximum load impedance
Output impedance
Power supply
※ 1 
Please keep power supply voltage over 12.0V for Voltage output type
 
to get 0-10V analog output correctly.
Functions of components
M12 5pin
Connector
● Control panel
Display
M8 4pin
Connector
ALrN
hdct
rESt
diSP
Extension mode
Extension mode is chosen by pressing "+" and "-" buttons at a time for 1 second.
Parameters in Extension mode must be set correctly otherwise it might not work correctly.
Please use with default setting when changing parameters is not needed.  ( " * " means default setting)
hYSt
NtoP
thrE
tout
inct
2Ero
SEnS
Setup
● Changing mode
While it's "Teach mode", "Setup mode" or "Extension mode", you can change the mode 
to "Measurement mode" by pressing "ZERO/RUN" button.
While it's "Setup mode" or "Extension mode", the LED "MANUAL" is lit.
CD22-15
CD22-35
CD22-100
CD22M-15
CD22M-35
CD22M-100
15mm
35mm
100mm
±5mm
±15mm
±50mm
Red laser Diode (wave length 655nm)
Max. output: 390 µW
※ 3
Max. output: 1mW
Suffi x nul: CLASS 1 / 2: CLASS 2 (Laser Notice No.50)
500 * 700µm
450 * 800µm
600 * 700µm
0.1% of F.S.
0.1% of F.S.
0.1% of F.S.
1µm
6µm
20µm
500µs / 1000µs / 2000µs / 4000µs / AUTO
● Changing parameters
±0.02% / ℃ of F.S.
±0.02% / ℃ of F.S.
±0.05% / ℃ of F.S.
You can choose and adjust the parameters by pressing "+" and "-" buttons.
Laser indicator: Green / Zero reset indicator: Red
The mode will be changed to "Measurement mode" by pressing "ZERO/RUN" button.
Output indicator: Orange / Mode indicator: Red
Laser OFF, Teaching, Sample & Hold, One shot, Zero reset
NPN/PNP max.100mA/DC30V ((Residual voltage 1.8 V max.)
70mA max. including Analog output current
Reverse connection protection, Over current protection
IP67 including connection part
-10 ~ 50℃ / 35 ~ 85% RH without freasing or condensation
-20 ~ 60℃ / 35 ~ 85%/RH
Incandescent lamp: 3,000 lx max.
10 ~ 55Hz, Double amplitude 1.5mm, X,Y,Z for 2 hours
500mm/s
2
( approx. 50G) X,Y,Z 3 times each
Teach mode
Case: Aluminum/SUS316L, Front lens: PPSU, Display: PET
Aluminum case with M12 connector : Approx. 60g including
300mm cable with connector
SUS case with M12 connector type : Approx. 90g including
300mm cable with connector
Aluminum case with M8 connector : Approx. 40g
SUS case with M8 connector : Approx. 70g
NEnu
2
(13.5%) at the center. There may be leak light other than the specifi  ed 
NodE
CD22 -
V
CD22 -
A
CD22 -
-485
Voltage output
Current output
RS-485 type
※ 1
0 ~ 10V
4 ~ 20mA
FGS2
300
100
DC12-24V ±10%
※ 1
nEAr
Miscellaneous function
cLNP
hoLD
0000
hoLD
hdct
YES
no
on
oFF
0. 1 23
NAH
Pt5
Pt4
Pt3
Pt2
Pt1
bASE
P400
Attention: Not to be Used for Personnel Protection.
P200
Never use these products as sensing devices for personnel protection. Do-
P100
ing so could lead to serious injury or death. These sensors do not include 
the self-checking redundant circuitry necessary to allow their use in per-
sonnel safety applications. A sensor failure or malfunction can cause either 
off
an energized or de-energized sensor output condition.
100N
Please consult our distributors about safety products which meet OSHA, 
ANSI and IEC standards for personnel protection.
SaNp
1
256
0. 1 23
Auto
N__6
N__1
1Pt
FGS2
2Pt
tch
tch
FAr
tch
0. 0 00
Loc
Loc
uLoc
http://www.optex-fa.com/rohs_cn/
● Specifi  cations and equipment are subject to change without
      any obligations on the part of manufacture.
● For more information, questions and comments regarding
      products, please contact us below.
91 Chudoji Awata-cho Shimogyo-ku Kyoto 600-8815 Japan
TEL: +81-(0)75-325-1314
FAX: +81-(0)75-325-2936
Website : http://www.optex-fa.com

Advertisement

loading

Summary of Contents for Fastus CD22 Series

  • Page 1 Specifi  cations Setup Connection diagram ● Part number legend Displacement sensor ■ NPN type ● Changing mode CD22 Series While it's "Teach mode", "Setup mode" or "Extension mode", you can change the mode  Brown : +V to "Measurement mode" by pressing "ZERO/RUN" button. DC 12~24V While it's "Setup mode" or "Extension mode", the LED "MANUAL" is lit. CD22-15 CD22M-15 CD22-35 CD22M-15 CD22-100 CD22M-100 3.3V Instruction manual : External input - Thank you for purchasing CD22 series. We hope you are satisfi  ed with its performance. - Please read this manual carefully and keep it for future reference. ● Specifi cations per measurement range...
  • Page 2 C D 2 2 mEnu To Setup mode Pin No. _- _ _ _ _ _ _ _ _ _ Color Description CD22 Series Laser Class ● Nul : Class 1 Brown DC12-24V ± 10% ● 2 : Class 2 ー...