Analog Output Range - Fastus LS Series User Manual

2d displacement sensor
Table of Contents

Advertisement

5.8.5

Analog Output Range

Sets the output range of the analog current output.
To set this range, set arbitrary upper and lower limits on the output.
The default output range is shown in the following figure.
The analog output resolution of the LS series is approximately 0.4 μA.
[Setting target:] Analog output
Tips
Set the "20mA" and "4mA" input values so that they meet the following conditions.
If the following conditions are not met, analog output will not be performed correctly.
• The "20mA" input value must be greater than the "4mA" input value.
• The difference between the "20mA" and "4mA" input values must be 1.000 or more.
Ramco National
24mA
20mA
12mA
4mA
0mA
-25mm
Figure: Analog output operation
800-280-6933 | nsales@ramcoi.com
0mm
25mm
Output Settings
5-37