The LS series performs measurements according to the following flow. Settings are also performed for each
of these items.
(1) Trigger
● Images are captured when the set conditions are met.
(2) Camera
● An image is captured based to the settings.
(3) Profile acquisition
● The profile (the sectional profile made by the reflected laser light) is acquired from the image.
(4) Area measurement
● The specified position within the profile is measured.
(5) Area calculation
● If necessary, the measured result of the area is calculated.
(6) Result judgment and output
● The measured result is compared against the threshold, and then the judgment result is output.
Tips
With the LS series, you can save settings related to measurements in "banks." Up to eight banks can
be saved.
Reference
For details on banks, see "5.9.1 Banks."
Ramco National
Laser control input
Trigger signal
Judgment output (control output)
Analog output
Camera imaging
 Camera settings
Profile
 Profile settings
Area measurement
 Area settings
Area calculation
 Calculation settings
Result judgment and output
Out 1
Out 2
 Output settings
Out 3
Analog