2.1.2
Setup and Measurement Process
The LS series performs measurements according to the following flow. Settings are also performed for each
of these items.
(1) Trigger
● Images are captured when the set conditions are met.
(2) Camera
● An image is captured based to the settings.
(3) Profile acquisition
● The profile (the sectional profile made by the reflected laser light) is acquired from the image.
(4) Area measurement
● The specified position within the profile is measured.
(5) Area calculation
● If necessary, the measured result of the area is calculated.
(6) Result judgment and output
● The measured result is compared against the threshold, and then the judgment result is output.
Tips
With the LS series, you can save settings related to measurements in "banks." Up to eight banks can
be saved.
Reference
For details on banks, see "5.9.1 Banks."
Ramco National
Laser control input
Trigger signal
Judgment output (control output)
Analog output
Camera imaging
Camera settings
Profile
Profile settings
Area measurement
Area settings
Area calculation
Calculation settings
Result judgment and output
Out 1
Out 2
Output settings
Out 3
Analog
800-280-6933 | nsales@ramcoi.com
Before Using the LS Series
Output is
stopped
during
settings.
www.Optex-Ramco.com
2-3