Timing Charts
7.4.2

I/O

Trigger
z
z
Trigger input
Ready output
Measured value
Strobe output
Trigger delay
time
Tips
• When "Trig action" is set to "Cont," the ready output is not generated.
• Strobe output is generated when the measured value is updated.
• Input constant of external input is 150 μs (ON → OFF) and 25 μs (OFF → ON).
Offset
z
z
The offset input operation varies depending on the value of the "Offset target" setting.
The offset input operation is executed when input turns off.
● When "Offset target" is "Indivi"
Input time
230 ms or less
430 ms or less
630 ms or less
830 ms or less
1030 ms or less
1230 ms or less
More than 1230 ms Clear all the offsets as a batch.
● When "Offset target" is "All"
Input time
330 ms or less
More than 330 ms
● When "Offset target" is "OUT1" to "OUT3"
Input time
330 ms or less
More than 330 ms
7-8
Ramco National
Input filter
Sampling
<500µs
period
(Internal processing time)
Set the offset on OUT1.
Set the offset on OUT2.
Set the offset on OUT3.
Clear the offset from OUT1.
Clear the offset from OUT2.
Clear the offset from OUT3.
Set the offset on OUT1 to OUT3 as a batch.
Clear all the offsets from OUT1 to OUT3 as a batch.
Set the offset on OUT1, OUT2, or OUT3.
Clear the offset from OUT1, OUT2, or OUT3.
800-280-6933 | nsales@ramcoi.com
Input filter
Output time
Operation
Operation
Operation
www.Optex-Ramco.com