.Main Screen
3.2.2

Input/Trigger

Set the operation of the input terminals and of the camera start trigger.
Setting item Bank Setting value/default value
IN1
N
Set the behavior of external input terminal IN1.
BANK1
Reset
IN2
N
Set the behavior of external input terminal IN2.
BANK2
Hold
IN3
N
Set the behavior of external input terminal IN3.
BANK3
Trigger
IN4
N
Set the behavior of external input terminal IN4.
Offset
LaserOFF
Reset
-
Execute the reset operation.
Wait...
Inner hold
-
Each time that the SET button is pressed, the hold function will be turned on or off.
The condition to enable this function is: IN2: BANK2.
OFF
ON
Inner trig
-
Each time that the SET button is pressed, the trigger will be turned on or off.
The condition to enable this function is: IN3: BANK3.
OFF
ON
Input polar
N
Set the operation polarity of the external input terminals.
N.O.
N.C.
Trig action
Y
Set the measurement operation to perform when trigger input is received.
Cont
1shot
Count
Trig count
Y
Set the count to use when "Trig action" is set to "Count."
The condition to enable this function is: Trig action: Count.
1 to 4095 [1]
Inp filter
N
Set the external input filter time to prevent chattering.
5 to 1275 [5]
Trig delay
Y
Set the delay time between the trigger meeting the camera conditions and the camera
actually taking images.
5 to 20475 [5]
Offset target
N
Select the target on which to execute the offset.
The condition to enable this function is: IN4: Offset.
Indivi
All
OUT1
OUT2
OUT3
3-6
Ramco National
IN1 is used as the first bit for switching banks.
IN1 is used as the reset input terminal.
IN2 is used as the second bit for switching banks.
IN2 is used as the hold input terminal.
IN3 is used as the third bit for switching banks.
IN3 is used as the trigger input terminal.
IN4 is used as offset input.
IN4 is used as the laser emission stop input.
This is displayed when the reset operation is being executed.
The trigger turns on when input is applied.
The trigger turns off when input is applied.
Measurements will be performed continuously.
One measurement will be performed when trigger input is received.
When the predetermined number of trigger inputs are
received, one measurement will be performed.
[Unit: Number of times]
[Unit: μs] * You can set this value in steps of 5 μs.
[Unit: μs] * You can set this value in steps of 5 μs.
Depending on the input time, the offset will be executed on
or cleared from OUT1, OUT2, or OUT3 or on all of these.
The offset will be executed on or cleared from all of OUT1,
OUT2, and OUT3.
The offset will be executed on or cleared from OUT1.
The offset will be executed on or cleared from OUT2.
The offset will be executed on or cleared from OUT3.