Graph Items (Area 1 To Area 4); Calc Items (Calculation 1 And Calculation 2) - Fastus LS Series User Manual

2d displacement sensor
Table of Contents

Advertisement

Graph/Calc
3.4.1

Graph Items (Area 1 to area 4)

You can use the graph display settings to configure the following items.
Setting item Bank Setting value/default value
Graph scale
Y
Expand or shrink the display time axis (the horizontal axis).
1 to 6 [1]
Graph range
Y
Expand or shrink the measured value display range (the vertical axis).
0 to 6 [0]
Span
Y
Set a span (multiplier) on the measured values.
0.001 to 1.999 [1.000]
Average
Y
Set the number of times over which to perform the moving average of the measured values.
1 to 1023 [32]
Hold
Y
Select the measured result hold operation.
None
Sample
Peak
Bottom
Reference
For details on the graph display settings, see "5.7 Calculation Settings."
3.4.2

Calc Items (Calculation 1 and calculation 2)

You can use the area calculation settings to configure the following items.
Setting item Bank Setting value/default value
Graph scale
Y
Expand or shrink the display time axis (the horizontal axis).
1 to 6 [1]
Graph range
Y
Expand or shrink the measured value display range (the vertical axis).
0 to 6 [0]
Span
Y
Set a span (multiplier) on the measured values.
0.001 to 1.999 [1.000]
Hold
Y
Select the measured result hold operation.
None
Sample
Peak
Bottom
Calc target1
Y
Select the area for calculation target 1.
Area1
Area2
Area3
Area4
Operator
Y
Select the operator of the calculation formula.
+
-
Calc target2
Y
Select the area for calculation target 2.
Area1
Area2
Area3
Area4
Reference
For details on the area calculation settings, see "5.7 Calculation Settings."
3-18
Ramco National
[Unit: Number of times]
The measured result will be output as-is. (Hold input will be ignored.)
The measured value during hold input will be output.
The maximum value during the hold input period will be output.
The minimum value during the hold input period will be output.
The measured result will be output as-is. (Hold input will be ignored.)
The measured value during hold input will be output.
The maximum value during the hold input period will be output.
The minimum value during the hold input period will be output.
Calculation target 1 + calculation target 2
Calculation target 1 - calculation target 2
800-280-6933 | nsales@ramcoi.com
General description
General description
www.Optex-Ramco.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ls-100cnLs-100cp

Table of Contents