Quick Setup

2.2 Quick Setup
2.2.1

Basic Measurement Settings

You can take basic measurements simply by setting the following three items. Configure the settings from
the sensor or from the LS-Navigator setup software.
● Shutter time
● Area
● Output conditions
Reference
For the actual screens and for information on the operations, see the following pages.
• Configuring settings from the sensor  "3.3 Setting"
• Using LS-Navigator  "4.3 LS-Navigator Screen and Operating Method"
1
Set the shutter time.
Position the measurement target, and then perform automatic adjustment. The optimum shutter time will
be set.
2
Set the area.
Use the area setting to specify what part you will measure and how that part will be measured.
(1) Measurement area
● Set what part within the measurement range will be measured. The set area must intersect the
profile (the sectional waveform).
(2) Measurement function
● Set the measurement function. You can select from functions such as height and width.
Reference
For details on the area settings, see "5.6 Area Settings."
3
Set the output conditions.
Configure the settings related to the output of the measured results. First, specify the judgment and
output target area.
● Output target
Select the target area (area 1 to area 4 and calculation 1 and calculation 2).
(1) Measurement output
The product judges whether the measurement is a pass or a fail, and then outputs the result.
● Upper limit/lower limit
(2) Analog current output (4 to 20 mA)
● 4 mA/20 mA
Set the lower and upper limits of the analog output range.
2-4