Profile Settings

5.5 Profile Settings
5.5.1
Profile Extraction Settings
Target
z
z
Select the measurement target from "Normal," "Gap," and "Semi-trans." "Normal" is standard.
Use this setting to specify what parts of the received light waveform to use as measurement data.
a) Normal
The peak position of the received light waveform will be
measured.
The center is measured, excluding the data from the point
where the amount of light is largest to the reject level, .
b) Gap
Level differences that have sudden height changes will be
measured.
The measurement method is the same as the "Normal"
setting, but two measured values are output from one received
light waveform.
Tips
The difference in measured results for level differences with the "Normal" and "Gap" settings is shown
below.
With the "Normal" setting, level difference sides cannot be measured accurately. The larger the level
difference, the wider the parts for which measurement is not possible.
[Operation difference for a profile that has level differences]
Actual profile
5-16
Ramco National
Image
800-280-6933 | nsales@ramcoi.com
Reject level
Reject level (difference)
Profile when using
the "Gap" setting
Profile when using the "Normal" setting
www.Optex-Ramco.com
Measured
value
Measured
value 1
Measured
value 2