Troubleshoot Temperature Alarms In Ex Series Switches - Juniper EX4100 Hardware Manual

Hide thumbs Also See for EX4100:
Table of Contents

Advertisement

Table 42: Chassis Component Alarm Conditions on EX4100 and EX4100-F Switches
Chassis
Alarm Condition
Component
The /var partition is
full.
A rescue configuration
is not set.
The feature usage
requires a license, or
the license for the
feature usage has
expired.

Troubleshoot Temperature Alarms in EX Series Switches

IN THIS SECTION
Problem | 204
Cause | 205
Solution | 205
Problem
Description
EX Series switches trigger a temperature alarm FPC 0 EX-PFE1 Temp Too Hot when the switch temperature
becomes too hot.
Alarm Severity
Remedy
Major
Clean up the system file storage space on the
switch. For more information, see
System Storage
Minor
request system configuration rescue
Use the
save
command to set the rescue
configuration.
Minor
Install the required license for the feature
specified in the alarm. For more information,
see
Understanding Software Licenses for EX
Series
Switches.
(Continued)
Freeing Up
Space.
204

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ex4100-f