Connect The Ex4100 And Ex4100-F Switch To External Devices - Juniper EX4100 Hardware Manual

Hide thumbs Also See for EX4100:
Table of Contents

Advertisement

c. Ensure that the pins are fully inserted into the terminal connector.
d. Use the screwdriver to tighten each screw on the terminal connector until snug. Do not
overtighten. Apply 4.5 lb-in. (0.51 Nm) of torque to the screws.
5. Insert the terminal connector (with the power cable attached) into the power supply socket on the
switch and secure it by tightening the two screws on either side of the terminal connector (see
91 on page
144).
Figure 91: Securing the Terminal Connector to the DC Power Inlet
NOTE: To supply sufficient power, terminate the DC input wiring on a facility DC source that
is capable of supplying a minimum of 7.5 A at –48 VDC.
6. Connect the other end of the power cable to the power source.
7. Close the input circuit breaker.
8. Verify that the IN OK and the OUT OK LEDs are lit green and on steadily.
Connect the EX4100 and EX4100-F Switch to
External Devices
IN THIS SECTION
Connect a Device to a Network for Out-of-Band Management | 145
144
Figure