Juniper EX4100 Hardware Manual page 212

Hide thumbs Also See for EX4100:
Table of Contents

Advertisement

Table 42: Chassis Component Alarm Conditions on EX4100 and EX4100-F Switches
Chassis
Alarm Condition
Component
Temperature
The temperature
inside the chassis
reached the yellow or
amber alarm limit.
The temperature
inside the chassis
reached the red alarm
limit.
Management
The Management
Ethernet interface
Ethernet link is down.
Routing Engine
The /var partition
usage is high.
Alarm Severity
Remedy
Minor
Check the fan.
Open a support case using the Case
Manager link at
support/, or call 1-888-314-5822 (toll-
free within the United States and Canada)
or 1-408-745-9500 (from outside the
United States).
Major
Check the fan.
Open a support case using the Case
Manager link at
support/, or call 1-888-314-5822 (toll-
free within the United States and Canada)
or 1-408-745-9500 (from outside the
United States).
Major
Check whether a cable is connected to
the Management Ethernet interface or
whether the cable is defective. Replace
the cable, if required.
If you are unable to resolve the problem,
open a support case using the Case
Manager link at
support/, or call 1-888-314-5822 (toll-
free within the United States and Canada)
or 1-408-745-9500 (from outside the
United States).
Minor
Clean up the system file storage space on the
switch. For more information, see
System Storage
(Continued)
https:/ /www.juniper.net/
https:/ /www.juniper.net/
https:/ /www.juniper.net/
Freeing Up
Space.
203

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ex4100-f

Table of Contents