Juniper EX4100 Hardware Manual page 51

Hide thumbs Also See for EX4100:
Table of Contents

Advertisement

Table 6: SYS, ALM, and MST Chassis Status LEDs on EX4100 and EX4100-F Switches
LED Label
ALM
MST
Table 7 on page 43
describes the cloud LED (labeled CLD) on an EX4100 and EX4100-F switch. The
table also describes the colors on the switch and the status that the colors indicate.
Color
Red
Amber
Unlit
Green
State and Description
A major hardware fault—such as a temperature alarm or a
power failure alarm—occurred, and the switch is halted.
A major alarm indicates a critical error condition that
requires immediate attention (see
Alarm Conditions on EX4100 and EX4100-F Switches" on
page
201).
A minor alarm—such as a software or a hardware error—
occurred. Power off the switch and then power it back on.
Monitor the switch to see whether it is working properly.
A minor alarm indicates a non-critical condition that
requires monitoring or maintenance. A minor alarm that is
left unchecked might cause interruption in service or
performance degradation.
No alarm is in effect, or the switch is halted.
In a standalone switch:
On steadily—The switch is functioning normally.
Off—The switch is powered off or is halted.
In a Virtual Chassis configuration:
On steadily—The switch is the primary switch in the
Virtual Chassis configuration.
Blinking—The switch is the backup switch in the
Virtual Chassis configuration.
Off—The switch is a linecard member in the Virtual
Chassis configuration, or the switch is halted.
(Continued)
"Chassis Component
42