Download Print this page

YASKAWA DX100 Maintenance Manual page 695

Hide thumbs Also See for DX100:

Advertisement

Alarm
Alarm Name
Sub
Number
Code
4969
CONVTR POWER
ERR(FREQUENCY
(SV)
4970
CONVTR POWER
ERR(PHASE
SEQ.)(SV)
4971
CONVTR POWER
ERR(PEAK)(SV)
4972
CONVTR
REGENERATE
OVERLOAD(SV)
4973
POSITION
ERROR(COLLISIO
N DETECT)
4980
DESTINATION
PULSE LIMIT
4981
DEST PULSE
MECHANICAL
LIMIT
4982
DEST
MECHANICAL
INTRF
4983
DEST
MECHANICAL
INTRF
4984
DESTINATION
SELF-
INTERFERENCE
Meaning
Cause
Board or software
failure
Primary power
supply failure
Primary power
supply failure
Primary power
supply failure
Setting error
Setting error
Setting error
Setting error
Setting error
Setting error
Remedy
Reset the alarm, and then execute the job.
If the error occurs again, replace the YSV01 board and the YCP01 board,
and then execute the job. Or replace the YIF01 board, and then initialize the
job. Then, load the data saved in the external memory device and execute
the job again.
Correct the converter primary power supply.
Correct the converter primary power supply.
Correct the converter primary power supply.
Check the deceleration time parameter.
(1)Check the following settings.
·Check the position setting for the step (move instruction) where the alarm
occurred.
(1)Check the following settings.
·Check the position setting for the step (move instruction) where the alarm
occurred.
(1)Check the following settings.
·Check the position setting for the step (move instruction) where the alarm
occurred.
(1)Check the following settings.
·Check the position setting for the step (move instruction) where the alarm
occurred.
(1)Check the following settings.
·Check the position setting for the step (move instruction) where the alarm
occurred.

Advertisement

loading