Alarm
Alarm Name
Sub
Number
Code
54
55
60
Meaning
Cause
YCP01 board failure (1)Turn the power OFF then back ON.
The transmission request without
Software operation
data was received in the Ethernet
error occurred
function.
YCP01 board failure (1)Turn the power OFF then back ON.
The transmission request of illegal
Software operation
data length was received in the
error occurred
Ethernet function.
YCP01 board failure (1)Turn the power OFF then back ON.
Illegal mail data ware received in
Software operation
the DNS task of the Ethernet
error occurred
function.
Remedy
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).