Alarm
Alarm Name
Sub
Number
Code
22
30
50
Meaning
Cause
An error occurred in the FTP client
Software operation
task creating process of the
error occurred
Ehternet function.
YCP01 board failure (1)Turn the power OFF then back ON.
An error occurred in the
Software operation
semaphore generation process for
error occurred
access exclusion of the Ethernet
function.
YCP01 board failure (1)Turn the power OFF then back ON.
An error occurred in the Web
Software operation
server task management ID
error occurred
getting process of the Ehternet
function.
YCP01 board failure (1)Turn the power OFF then back ON.
Remedy
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.