Download Print this page

YASKAWA DX100 Maintenance Manual page 281

Hide thumbs Also See for DX100:

Advertisement

Alarm
Alarm Name
Sub
Number
Code
61
62
63
64
Meaning
Cause
An error occurred in the DHCP
Software operation
interface of the Ethernet function.
error occurred
YCP01 board failure (1)Turn the power OFF then back ON.
The data acquisition process from
Setting error
the server did not complete within
regulated time.
YCP01 board failure (1)Turn the power OFF then back ON.
The data acquired from the server
Setting error
were found illegal in the DHCP of
the Ethernet function.
YCP01 board failure (1)Turn the power OFF then back ON.
An error occurred in the subnet
Setting error
mask acquisition process in the
DHCP of the Ethernet function.
Remedy
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
(1)Check the following settings.
·The DHCP server operation
· The network status
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
(1)Check the following settings.
· The DHCP server operation
· The network status
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
(1)Check the following settings.
· The DHCP server operation
· The network status

Advertisement