Download Print this page

YASKAWA DX100 Maintenance Manual page 208

Hide thumbs Also See for DX100:

Advertisement

Alarm
Alarm Name
Sub
Number
Code
0609
MEDAR
PARAMETER
ERROR
0610
MEDAR STEPPER
TRANSMIT
ERROR
0710
LADDER
INITIALIZE
ERROR
0720
LADDER
1
PROGRAM
ERROR
Meaning
Cause
MADER timer error
MADER timer error
Data error
YCP01 board failure (1)Turn the power OFF then back ON.
YIF board failure
An error was found in the relay No.
Data error
specification.
YCP01 board failure (1)Turn the power OFF then back ON.
Remedy
Refer to the instruction manual for the MEDAR function.
Refer to the instruction manual for the MEDAR function.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, initialize the appropriate data in maintenance
mode, and then load the data saved in the external memory device.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, initialize the appropriate data in maintenance
mode, and then load the data saved in the external memory device.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.

Advertisement

loading