5.1.5 Checking and Replacing Fuses
5.1.5.1 Power Supply Contactor Unit
(2FU),(1FU)
Fuse for AC control power supply
0218010P(10A 250V)
(4FU),(3FU)
Fuse for cooling fan
GP25(2.5A 250V)
5
Replacing Parts
5.1
Replacing DX100 Parts
The types of fuses on power supply contactor unit
(JZRCR-YPU01- ) are as follows
Parts No.
Fuse Name
1FU, 2FU
AC Control Power Supply
Fuse
3FU,4FU
AC Cooling Fan Fuse
2FU
1
0
A
3FU
CN601
NCM
CN606
CN606
Replacement Fuse of the Power Supply Contactor Unit
If the fuse is blown, replace it with the same type of fuse (supplied or
spare parts).
5-19
.
Specification
0218010P
250V,10A, Time Lag Fuse
(LITTEL)
GP25, 2.5A, 250V
(Daito Communication Apparatus
Co., Ltd.)
CN601
CN601
CN610
CN611
CN611
CN610
1FU
2FU
1
FU
CN607
1
0
A
4FU
CN607
SVMX1
SVMX2
SVMX1
SVMX2
CN612
CN612
CN605
CN605
CN604
CN604
CN603
CN603
CN602
CN602

Advertisement