Download Print this page

YASKAWA DX100 Maintenance Manual page 657

Hide thumbs Also See for DX100:

Advertisement

Alarm
Alarm Name
Sub
Number
Code
4598
PAINTOUT
1
ERROR
4599
SERVO
COMMAND
ERROR
4603
WIRE STICKING
4604
SPECIFIED
ERR(ABSO
RECOVER AXIS)
4605
SETTOOL ERROR 1
4606
LACK OF GLOBAL
VARIABLE AREA
4607
WRONG
1
EXECUTION OF
MACRO INST
2
3
Meaning
Cause
The parameter setting for the
Setting error
universal input group number is
incorrect.
An attempt was made to issue the
Software operation
command while the servo control
error occurred
processing has not completed.
Sub Code: Servo CPU bit number
Sub Code: Welder number
Setting error
Setting error
The difference between the current
Setting error
tool constant and a new set value
exceeded the allowable range
(parameter set value).
Software operation
error occurred
The execution macro job is not set. Setting error
The interrupt macro job is not set.
Setting error
An attempt was made to start the
Setting error
job that could not be started by the
macro instruction.
Remedy
(1)Check the following settings.
·Check the settings for the AxP011.
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(1)Check the following settings.
·Remove the cause of wire stick.
(1)Check the following settings.
·Registration for the home position correction data.
(1)Check the following settings.
·Correct the job so that the setting value of tag is allowable value.
·Set the allowance amount of the tool data automatic setting function
maximum deviation (S3C900) to large value.
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(1)Check the following settings.
·Check the settings for execution macro job.
(1)Check the following settings.
·Check the settings for interrupt macro job.
(1)Check the following settings.
·Check the settings for macro job.

Advertisement