Alarm
Alarm Name
Sub
Number
Code
4054
MEMORY
ERROR(PAINTING
SPECIAL)
4055
MEMORY
ERROR(CCV-
PAINT TABLE)
Meaning
Cause
Sub Code: File number
Data error
YCP01 board failure (1)Reset the alarm.
YIF board failure
Sub Code: File number
Data error
YCP01 board failure (1)Reset the alarm.
YIF board failure
Remedy
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the painting device characteristics file
in maintenance mode, and then load the painting device characteristics file
saved in the external memory device.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF board, and then load
the CMOS.BIN saved before alarm occurred.
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the painting CCV file in maintenance
mode, and then load the painting CCV file saved in the external memory
device.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF board, and then load
the CMOS.BIN saved before alarm occurred.