Alarm
Alarm Name
Sub
Number
Code
1309
HARDWARE
ERROR(CONVER
TER)
1310
CHARGE
ERROR(CONVER
TER)
1311
A/D DETECTION
ERROR(CONVER
TER)
1312
ID
ERROR(CONVER
TER)
1313
COMMAND
ERROR(SERVO)
1314
VERIFY
ERROR(PARAMET
ER)(SERVO)
Meaning
Cause
Software operation
error occurred
Module
failure(converter)
Module
failure(converter)
Primary power
failure
Module
failure(converter)
Sub Code: Signifies the converter
Module
in which the alarm occurred
failure(converter)
Software operation
error occurred
Software operation
error occurred
Remedy
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the SERVOPACK.
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the SERVOPACK.
Check if the primary power supply voltage does not drop with a tester, etc..
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the SERVOPACK.
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the SERVOPACK.
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
(1)Reset the alarm.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).